1.
Indian J Surg Oncol ; 12(2): 272-278, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34295070

RESUMO

The ACOSOG Z0011 study, heralded as a "practice changing" trial, suggested that women with T1-2 breast cancer with 1-2 SLN+, undergoing breast conservation therapy, need not be offered further ALND. However, whether these results are applicable to all women in the Indian setting, it remains debatable. A retrospective audit of all cN0 operated from 2013 to 2018 was conducted. We analyzed the percentage of additional LN positive (LN+) in the ALND group and compared it to the ACOZOG Z11 trial. Of the 2350 cN0 with EBC who underwent LAS, 687 (29%) had positive lymph nodes on final histopathology. Five hundred ninety-seven (86.9%) patients had 1-2 LN+, 40 (5.8%) patients had 3 LN+, and 50 (7.3%) had 4 or more nodes positive. Demographic features in the ACOSOG Z11 are different from those in our study, looking at ACOZOG Z11 versus our cohort-median pT 1.7 cm versus 3 cm, 45% micrometastasis versus 99.16% macrometastasis, and 28-30% grade 3 tumors versus 73.7%. In our cohort 31.82% of the 1-2 LN positive had additional LN+ on ALND. Keeping in mind the difference in clinicopathological features between our cohort and that of ACOZOG Z0011 and that 31.82% of women had additional LN+ on ALND, it may not be appropriate to apply the results of the ACOSOG Z0011 trial directly to our general population. Possibly, only a select subset of patients who match the trial population of the ACOSOG Z11 could be offered observation of the axilla and validated nomograms can be used to identify high-risk patients.

2.
Indian Pediatr ; 49(2): 145-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22410515

RESUMO

We describe a case of corrosive tracheo-esophageal fistula following button battery ingestion in a 1-year old nonverbal pediatric patient. The delay in diagnosis was caused by failure to obtain correct history and failure to detect opacity of the battery in the neck at the first visit. The large fistula was successfully treated with division and repair with non absorbable sutures, with interposition of strap muscles between separated trachea and esophagus.


Assuntos
Fontes de Energia Elétrica/efeitos adversos , Esôfago , Corpos Estranhos/complicações , Traqueia , Fístula Traqueoesofágica/etiologia , Corpos Estranhos/diagnóstico por imagem , Humanos , Lactente , Masculino , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...